I. Safety Instruction
1. For your utmost security, it is essential to thoroughly peruse the instructions prior to any initial operation. Ensure the power is entirely OFF before making any connection.
2. Prior to commencing operations, it is imperative to clear memory. (Ref: Erasing ALL learned/memorized Transmitters)
3. Avoid learning the remote control when the motor is in operation to prevent any potential mis-operation.
4. Be aware that the received signal can be subject to interference from other communication devices, such as wireless control systems within the same frequency range.
5. Controlling high-risk equipment or systems, such as cranes, is strictly prohibited.
6. This device is strictly intended for manual remote control and wireless control systems that must not pose any threat to life or property
in the event of a running failure, or when all security risks have been mitigated.
7. Ideal application is in a dry indoor environment or within an electric appliance setting.
8. Note that excessively long connected wires may destabilize receiver performance.
II. Technical parameters
| Working voltage | 12-24VAC/DC |
| Temperature range | -20ºC to 60ºC |
| Working frequency | 433.92MHz |
| Stored transmitters | Rolling code 30 |
| Relay contact load capacity | 1A,30V DC |
III. Set up and working process
1. Learning transmitter: Initiate by pressing the learning button S1 on the receiver, indicated by a red LED. Press any transmitter button twice; the LED flickers, stays on briefly, then turns green, signaling successful learning.
2. Deleting transmitter: Hold the learning button S1 for an extended period. The indicating lamp will remain red for 8 seconds, then shift to green.
Release the learning button. The LED will turn red for 2 seconds then revert to green, confirming successful deletion.
3. Latch and non-latch: With no jumper on LATCH A, it functions as non-latch. With a jumper present, it switches to latch mode.
4. Self-learning function: Utilize a pre-learned transmitter as the primary transmitter to activate the learning function for a new transmitter without pressing any learning button. (Press buttons 1 and 2 simultaneously, then button 2 to enter the learning process.)
IV. Operation
1. To enable the receiver to learn from the transmitter, press any button on the transmitter.
2. The receiver can only learn one button per transmitter. If button 2 is learned after button 1, button 1 will be replaced.
3. For non-latch mode: Maintain pressure on the button to keep the receiver active. Release it to stop operation.
4. For latch mode: Press the button to commence receiver operation. Press again to halt the process.