  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
  • Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
Find Similar Products

Basic Info.

Model NO.
R5111
Certification
CE, RoHS
Channel
2CH
Receive Frequency
433.92MHz
Transmission Rate
10~20Kbps
Code
Rolling Code
Specification
60*35*22mm
Trademark
Hiland
Origin
China
Production Capacity
10000PCS/Month

Product Description

Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111

I. Safety Instruction

1. For security, please read instructions carefully before initial operation; making sure that the power is off before connection. 
2. Please clear the memory before initial operation. (Ref: Erasing ALL learned/memorized Transmitters)
3. Do not learn the remote control when motor is operating in order to avoid mis-operation.
4. The received signal may be interfered by other communication devices. (e.g. the wireless control system with the same frequency range)
5. It is forbidden to control the high-risk coefficient equipment / system. (e.g. cranes)
6. It is used only for the manual remote control and wireless control equipment / system which must not endanger life or property 
during running failure, or its security risks have been eliminated
7. It should be applied in dry indoor place or in the electric appliance place.
8. If connected wire is too long , the receiver may work unstable

II. Technical parameters
1. Working voltage:12-24VAC/DC 
2. Temperature range:-20ºC to 60ºC
3. Working frequency:433.92MHz
4. Stored transmitters: fixed code 60PCS
5. Relay contact load capacity::1A,30V DC

III. Set up and working process
1. Learning transmitter: Press the learning button of the receiver, then LED is red. Press any one of the transmitter twice times, LED flickers and continues on several seconds, then off. It is indicated the learning is successful.
2. Deleting transmitter: Press the learning button for a long time, the indicating lamp is red for 8 seconds, and then off, release the learning button, LED is red for 2 seconds and then off; complete the deleting transmitter.
3. Latch and non-latch: Latch A is for channel 1,B is for channel 2. It's non-latch when no jumper on LATCH, It's latch when there's jumper on LATCH.
4. Self-learning function: Use the transmitter that already has been learned as old transmitter, press button 1 and button 2 at the same time and then press button 2 to let the receiver enters into the learning process .In this way , new transmitter can be learned refer 4.1 without press the learning button S1 on the receiver.

IV. Operation
1. Transmitter button 1 controls receiver channel 1, transmitter button 2 controls receiver channel 2, no matter users use button 1 to learn or button 2
2. Transmitter button 3 controls receiver channel 1, transmitter button 4 controls receiver channel 2, no matter users use button 3 to learn or button 4
3. Non-latch: Keep pressing the button, receiver starts working. Release the button, receiver stops working .
4. Latch: Press the button, receiver starts working. Press button again, receiver stops working .
5. The function of latch/non-latch for channel 1 and channel 2 is separate and it could be set up according to users' requirement.

V.Certification

CE-R5XXX-EMC
Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111
CE-R5XXX-LVD
Hiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Our ExhibitionHiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Company profileHiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111Packaging And LogisticsHiland 2-Channel Rolling Code 12-24V AC/DC Receiver R5111FAQ
1. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.What can you buy from us?
Transmitter,Tubular Motor Receiver,Sliding Gate Opener,Garage Door Opener,Photocell

3. Why should you buy from us not from other suppliers?
Hiland is professional designer and qualified manufacturer of the automatic door control systems.We have 15 years experience We
have sliding/garage/swing/rolling shutter opener and control systems,transmitters,receivers,photocell,flash lamp,keypad etc.

Q4.How can i get a price of needed garage door opener?
A: Please give the exactly size and quantity of your required door. We can give you a detail quotation based on your requirements.

Q5.We want to be your agent of our area. How to apply for this?